CISPR 25 CHAMBER
Purpose
The CISPR 25 Chamber is developed with the focus on radiated emissions in a semi-anechoic environment over a frequency range from 70 MHz to 18 GHz for vehicle component testing in accordance with CISPR 25.
Consisting of a fully modular system for shielding and absorbers, the installed chamber can be set up stepwise and adapted to changes to the Equipment Under Test (EUT) sizes.
Technical Description
For vehicle Components testing:
- Chamber shielding dimensions: 5.5 x 4.3 x 3.3 m (l x w x h) approx.
- Space requirement inside building: 6.5 x 5.3 x 4.3 m (l x w x h) approx., depending on support type.
- Usable space inside: 4.6 x 3.4 x 2.7 m (l x w x h) approx.
- One door of 1.2 x 2.05 m clear opening with mechanical actuation aid. The door is equipped with a switch to be connected to the interlock system for amplifier auto power off.
For Vehicle testing:
- Chamber shielding dimensions: 7.9 x 6.4 x 3.6 m (l x w x h) approx.
- Space requirement inside building: 8.9 x 7.4 x 4.6 m (l x w x h) approx., depending on support type.
- Usable space inside: 6.9 x 5.4 x 3.0 m (l x w x h) approx.
- One door of 2.1 x 2.05 m clear opening with mechanical actuation aid. The door is equipped with a switch to be connected to the interlock system for amplifier auto power off.
- Fully galvanized modular shielding system made of 2 mm steel. Electromagnetic shielding performance of shielding compliant with EN 50147-1 and MIL STD 285:
Frequency |
Performance |
Field Component |
10 kHz |
60 dB |
H |
100 kHz |
80 dB |
H |
1 MHz |
100 dB |
H |
10 MHz |
100 dB |
E |
100 MHz |
100 dB |
E |
1 GHz |
100 dB |
PW |
10 GHz |
100 dB |
PW |
18 GHz |
100 dB |
PW |
- Modular absorber lining on the walls and ceiling by hybrid absorbers.
- Four honeycomb inserts for ventilation. Size 330 x 330 mm.
- Four illumination spots of 750 W.
- One three-phase power supply filter, 4 x 32A, max. 250V/440V 50 or 60 Hz for EUT and general power supply.
- Electrical distribution, necessary breakers, four single phase outlets 230 W, one three phase outlet 400 V, one switch for illumination.
- One detachable access panels (AP).
- One connecting points are integrated in the floor.
- One grounding rail.
- Integrated in the floor are two cable ducts, which feed the necessary cables from the access panels (AP) to the connecting points (CP).
- The facility has a host building attached support system. As option a self-supporting system is available.